• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Electrical Engineering News and Products

Electronics Engineering Resources, Articles, Forums, Tear Down Videos and Technical Electronics How-To's

  • Products / Components
    • Analog ICs
    • Connectors
    • Microcontrollers
    • Power Electronics
    • Sensors
    • Test and Measurement
    • Wire / Cable
  • Applications
    • Automotive/Transportation
    • Industrial
    • IoT
    • Medical
    • Telecommunications
    • Wearables
    • Wireless
  • Resources
    • DesignFast
    • Digital Issues
    • Engineering Week
    • Oscilloscope Product Finder
    • Podcasts
    • Webinars / Digital Events
    • White Papers
    • Women in Engineering
  • Videos
    • Teschler’s Teardown Videos
    • EE Videos and Interviews
  • Learning Center
    • EE Classrooms
    • Design Guides
      • WiFi & the IOT Design Guide
      • Microcontrollers Design Guide
      • State of the Art Inductors Design Guide
    • FAQs
    • Ebooks / Tech Tips
  • EE Forums
    • EDABoard.com
    • Electro-Tech-Online.com
  • 5G

2-W and 4-W board-mount supplies operate from 90 to 305-Vac inputs

September 15, 2017 By Lee Teschler Leave a Comment

The KAS series ac-dc power supplies is rated at 2 and 4 W. Accepting 90 to 305-Vac, 47-440-Hz inputs, these board-mounted converters will operate from 115, 230 and 277-V nominal inputs. Target applications include security systems, building automation, professional household appliances, portable equipment and products requiring a separate standby voltage.

KAS-24 The series has a double-insulated Class II construction, requiring no earth ground connection and has a 3-kVac primary-to-secondary isolation. Available output voltages are 3.3, 5, 8, 9, 12, 14, 15 and 24 V and no-load power consumption is less than 300 mW. The KAS units are encapsulated in a plastic-resin fiberglas sproviding additional protection against shock and vibration. The 2-W KAS2 measures 28.5×25.8×17.0 mm and the 4-W KAS4 37×27.5×17.5 mm.

The KAS2 will operate in ambient temperatures of -40 to +80°C, derating linearly to 40% load above 60°C. The KAS4 has a temperature range of up to -40 to +70°C, with model-dependent derating. All the power supplies are certified to IEC/EN/UL/CSA 60950-1 and are designed to meet IEC/EN 60335-1 with CE marking for the Low Voltage and RoHS2 Directives. The series is compliant to EN 55032-B (radiated and conducted) and will meet EN 55024 immunity standards with an external varistor.

More information: TDK-Lambda Americas, http://www.us.tdk-lambda.com/lp/products/kas-series.htm, 800-LAMBDA-4.

DesignFast Banner version: 2cc02f57

Filed Under: Power Electronic Tips Tagged With: tdklambda

Reader Interactions

Leave a Reply Cancel reply

You must be logged in to post a comment.

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Primary Sidebar

EE Training Center Classrooms

EE Classrooms

Featured Resources

  • EE World Online Learning Center
  • CUI Devices – CUI Insights Blog
  • EE Classroom: Power Delivery
  • EE Classroom: Building Automation
  • EE Classroom: Aerospace & Defense
  • EE Classroom: Grid Infrastructure
Search Millions of Parts from Thousands of Suppliers.

Search Now!
design fast globle

R&D World Podcasts

R&D 100 Episode 8
See More >

Current Digital Issue

June 2022 Special Edition: Test & Measurement Handbook

A frequency you can count on There are few constants in life, but what few there are might include death, taxes, and a U.S. grid frequency that doesn’t vary by more than ±0.5 Hz. However, the certainty of the grid frequency is coming into question, thanks to the rising percentage of renewable energy sources that…

Digital Edition Back Issues

Sponsored Content

Positioning in 5G NR – A look at the technology and related test aspects

Radar, NFC, UV Sensors, and Weather Kits are Some of the New RAKwireless Products for IoT

5G Connectors: Enabling the global 5G vision

Control EMI with I-PEX ZenShield™ Connectors

Speed-up time-to-tapeout with the Aprisa digital place-and-route system and Solido Characterization Suite

Siemens Analogue IC Design Simulation Flow

More Sponsored Content >>

RSS Current EDABoard.com discussions

  • Effect of variable gain amplifier and LNA on the input RF signal's phase
  • Code Optimization
  • Cosmos DB with AT commands by using SIM868e
  • Natural Convection Heatsink for 80W power dissipation?
  • simple LSB explanation please

RSS Current Electro-Tech-Online.com Discussions

  • Review of electric circuit with Arduino
  • ICM7555 IC duty cycle limit at high frequency?
  • How to quickly estimate lead acid battery capacity ?
  • Battery charging indicator circuit design
  • intro to PI

Oscilloscopes Product Finder

Footer

EE World Online

EE WORLD ONLINE NETWORK

  • 5G Technology World
  • Analog IC Tips
  • Battery Power Tips
  • Connector Tips
  • DesignFast
  • EDABoard Forums
  • Electro-Tech-Online Forums
  • Engineer's Garage
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips
  • Test and Measurement Tips
  • Wire & Cable Tips

EE WORLD ONLINE

  • Subscribe to our newsletter
  • Lee's teardown videos
  • Advertise with us
  • Contact us
  • About Us
Follow us on TwitterAdd us on FacebookConnect with us on LinkedIn Follow us on YouTube Add us on Instagram

Copyright © 2022 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy