Touchless, Holographic HMIs Prevent Disease Transfer
By R. Douglas McPheters, HoloTouch Inc., www.holotouch.com
The New York State Health Department’s June 30, 2009 Hospital-Acquired Infections Report has drawn serious attention of healthcare professionals and the public to the daunting challenges faced in eliminating contamination and disease transmission rampant in hospitals and other healthcare facilities. Unfortunately, this report and others spawned such Earth-shattering recommendations as the importance of washing hands while at work in healthcare facilities. While useful, that procedure was part of the syllabus for the health merit badge I earned on the way to becoming an Eagle Scout in the ‘50s. A much younger person might say “hello?”
We all have friends who’ve returned home from hospitals with serious infections contracted for reasons unrelated either to their reasons for seeking treatment in the first place or their medical procedures. My personal favorite is a now-deceased friend who entered a local hospital for implantation of a pacemaker and returned home with a staph infection in her foot. Regrettably, many laudable suggestions on ways to reduce the spread in healthcare facilities of diseases and infections, particularly in our virus and H1N1-laden world, however well-intended, can best be described as “feel good” measures akin to the ubiquitous anti-bacterial lotion dispensers we’ve all seen metastasizing in healthcare facilities and various public facilities. As I understand it, washing hands is important but useless unless pursued vigorously for at least 30 seconds. Sadly, many measures suggested as cheap or simple ways to reduce transmission of contamination and disease are destined to be unproductive because they either require overworked, distracted or disinterested people to do still one more thing or necessitate use of additional equipment or supplies that are not efficient, however well advertized.
Fortunately, touchless, holographic human-machine interfaces offer a simple solution that doesn’t require people to do more than they already do – they need only pass a finger through a holographic image, floating freely in the air, of what would otherwise be the keys or buttons of equipment to be operated. These HMIs for electronics and electro-mechanical equipment offer inexpensive and intuitive ways to bypass transmission of contamination, dirt and disease because there’s nothing to actually touch in using them. Touchless, holographic HMIs have only three essential and simple components: a full-color hologram of what would otherwise be keys or buttons of the equipment laminated on the back of an acrylic plate, an LED behind the acrylic plate that projects the hologram’s image into the air and a wave source sensor, usually infrared, also behind the acrylic plate, that is focused on the center of the freely floating holographic image. When a finger enters the holographic image, the sensor sends an actuation signal to the device. For example, take a look at the lowly, metal mushroom on the hospital wall that family, patients and staff elbow, hit, punch or shoulder to actuate the mechanism that opens exit doors. Not only is that device crawling with whatever was on the body, clothing or hands of all previous users (seldom if ever cleaned) but it must be regularly replaced due to heavy use and abuse. By contrast, touchless, holographic switches have no moving parts to fail under heavy use and only passing a finger through their colorful, holographic images, suspended in the air, is needed to open the doors. These components can be easily customized to a wide variety of electronic and electro-mechanical devices such as medical equipment, kiosks and doors, whether in primary hygiene sites such as operating rooms or less directly invasive venues such as healthcare facility corridors, examining rooms and public areas.
Leveraging Useful Skew By Sunit Bansal, Sumeet Aggarwal, & Kapil Narula, Freescale Semiconductor, Inc., www.freescale.com Introduction What is Clock Skew? Question: How Clock Skew helps in meeting timing? Lets assume that the path from flop1 to flop2 is violating by 250ps. Following is the sequence of steps that can be done to meet the timing using useful skew. 1. Identify the slack value “to” the violating register (flop2 in Fig2) The situation after pushing the clock is shown in Fig3. We can notice that now the timing paths are meeting: Useful Skew can be more useful We can make useful skew more useful by following our 3-pronged strategy. 2. Do Optimization of the design after finding all such occurrences. Following figure shows the slack values after optimization. 3. Remove the extra uncertainty after optimization. Now the slack would be 1.1ns. Now notice that before the strategy the slack was 0.75ns. Now it has changed to 1.1ns. Also, Slack to the violating register has changed back to -0.950ns. Corollary: The idea could be further extended to more register levels. Essentially we can generate more useful skew margin through cascading registers. For e.g Even after increasing the uncertainty, the path from the “violating register” (flop2) has a slack of 0.750ps. |