• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Electrical Engineering News and Products

Electronics Engineering Resources, Articles, Forums, Tear Down Videos and Technical Electronics How-To's

  • Products / Components
    • Analog ICs
    • Connectors
    • Microcontrollers
    • Power Electronics
    • Sensors
    • Test and Measurement
    • Wire / Cable
  • Applications
    • Automotive/Transportation
    • Industrial
    • IoT
    • Medical
    • Telecommunications
    • Wearables
    • Wireless
  • Resources
    • DesignFast
    • Digital Issues
    • Engineering Week
    • Oscilloscope Product Finder
    • Podcasts
    • Webinars / Digital Events
    • White Papers
    • Women in Engineering
  • Videos
    • Teschler’s Teardown Videos
    • EE Videos and Interviews
  • Learning Center
    • EE Classrooms
    • Design Guides
      • WiFi & the IOT Design Guide
      • Microcontrollers Design Guide
      • State of the Art Inductors Design Guide
    • FAQs
    • Ebooks / Tech Tips
  • EE Forums
    • EDABoard.com
    • Electro-Tech-Online.com
  • 5G

Handling the 48-to-12-V stepdown

February 4, 2021 By Lee Teschler

A multiphase, interleaved buck converter can reduce bus voltage down to something useful in data center server racks.

Brad Xiao, Nazzareno (Reno) Rossetti Maxim Integrated

Hyperscale data centers that dissipate hundreds of megawatts demand efficient power delivery beyond the ability of the traditional 12-V power supplies on old server motherboards. A data center on 12 V has a power usage effectiveness (PUE) of 1.1 at best. It wastes 10% of its power (tens of megawatts) on cooling and overhead. That wasted power could comfortably supply electricity to a small city with about 10,000 homes.

server power architecture
Typical 48-V server architecture today powers low-voltage (< 1.8 V), high-current loads like memories and microprocessors via an unregulated 12-V rail. An open-loop, unregulated 4:1 switched tank converter (STC) produces the unregulated 12 V. (STCs use LC resonant tanks to partially replace flying—i.e. floating with respect to ground–capacitors for energy transfer. High-efficiency 12-V voltage-regulating converters power the various loads.

The move from 12 to 48-V power brings several advantages. The server rack dissipates heat more efficiently, costs less, and can be smaller as a consequence of the reduced current (4x), copper losses (16x), and connector/bus bar sizing. In the power management architecture of a modern data center, different strategies are adopted to power different classes of loads like processors, memories, and peripherals. Peripherals such as PCIE and HDDs require a 12-V supply rail. One way to get the required 12 V is through use of a multiphase, interleaved, coupled-inductor-based 48-to-12-V step-down converter. This converter design is compact, efficient, and cost-effective.

The best strategy to power low-voltage (< 1.8 V), high-current loads like memories and microprocessors is to reduce the 48 V down to an unregulated 12-V rail. An open-loop, unregulated 4:1 switched-tank converter (STC) topology enables soft-switching operation with peak efficiency in the 98% to 99% range. From here, high-efficiency 12-V voltage regulator-converters power the various loads. Peripherals like PCIE and HDDs require a 12-V supply rail and currents up to 100 A (1.2 kW). In this case, a 48-to-12-V regulated, interleaved, multiphase dc-dc converter can do the job.

four phase
A four-phase, coupled-inductor configuration yields an outstanding 97.9% peak and 97.43% full-load efficiency (12 V, 100 A, 1.2 kW) with the interleaved buck controller.

Use of a four-phase interleaved dc-dc converter reduces ripple current and, hence, ripple voltage, compared to that of a single-phase converter. Lowering output current ripple and voltage ripple means fewer capacitors on the output, resulting in a smaller BOM. The four-phase architecture also requires fewer input capacitors.

The total input current is the sum of the four out-of-phase currents. Here, spreading the total input current over time reduces the total RMS value of the input current compared to that of a single-phase setup. This spreading makes possible a smaller input current-ripple filter. Another great benefit of a four-phase converter is a fast transient response and lower voltage overshoot/undershoot during load steps. Lower overshoots, in turn, allow a tighter voltage rail powering the electronic load with less headroom needed for transient droop, resulting in less power dissipated at the load.

Additional efficiencies can be had through use of a coupled inductor in which the inductor coils wind around a common magnetic core. Here, the winding orientation is such that the magnetic flux cancels out, resulting in less than a quarter of the ripple current compared to that of four uncoupled inductors. Extremely low ripple current yields the smallest BOM and highest efficiency.

regulator
The 8-to-60-V MAX15157B fixed-frequency, accurate current report, current-mode PWM controller drives two power MOSFETs in this buck configuration, allowing OPERATION as a 48-to12-V step-down regulator. Click to enlarge.

An example of a device that makes possible efficient 48-to-12-V conversion is the 8-to-60-V MAX15157B fixed-frequency, current-mode PWM controller. It drives two power MOSFETs in a buck configuration, synthesizing a 48-to-12-V step-down regulator. Four ICs–in conjunction with external discrete MOSFETs, capacitors, and a single coupled inductor–are interleaved for multi-phase operation. The switching frequency is controlled either through an external resistor setting the internal oscillator frequency or by synchronizing the regulator to an external clock. The device is designed to support switching frequencies ranging from 120 kHz to 1 MHz. Each IC is available in a 5×5-mm, 32-pin TQFN package and supports a -40 to +125°C junction temperature range. In a four-phase, coupled-inductor configuration, this topology yields an outstanding 97.9% peak and 97.43% full-load efficiency (12 V, 100 A, 1.2 kW).

48-to-12-V PCB
The 48-to-12-V PCB with a coupled inductor. The design easily fits on a motherboard. It fits in a quarter-brick footprint using one PCB side, in an eighth-brick footprint on two PCB sides.

The 48-to-12-V PCB layout with a coupled inductor can easily sit on the data server motherboard. It fits in a quarter-brick size on one side of a PCB and in an eighth-brick form factor on two PCB sides.

In a nutshell, high levels of efficiency available through use of such 48-to-12-V conversion techniques offer a path toward power usage effectiveness approaching unity in a not-so-distant future.

You may also like:


  • Picking reliable power supplies

  • Switched capacitor power conversion for electronic systems

  • Measuring a sense-resistor’s voltage drop, Part 1: Sensing issues

  • Thermal management considerations for board-mounted dc/dc converters

  • The basics of AC-line isolation for safety, Part 1: The…
DesignFast Banner version: 03eceadf

Filed Under: FAQ, Featured, Power Electronic Tips Tagged With: maximintegratedproductsinc

Primary Sidebar

EE Training Center Classrooms

EE Classrooms

Featured Resources

  • EE World Online Learning Center
  • CUI Devices – CUI Insights Blog
  • EE Classroom: Power Delivery
  • EE Classroom: Building Automation
  • EE Classroom: Aerospace & Defense
  • EE Classroom: Grid Infrastructure
Search Millions of Parts from Thousands of Suppliers.

Search Now!
design fast globle

R&D World Podcasts

R&D 100 Episode 7
See More >

Current Digital Issue

April 2022 Special Edition: Internet of Things Handbook

How to turn off a smart meter the hard way Potential cyber attacks have a lot of people worried thanks to the recent conflict in Ukraine. So it might be appropriate to review what happened when cybersecurity fi rm FireEye’s Mandiant team demonstrated how to infiltrate the network of a North American utility. During this…

Digital Edition Back Issues

Sponsored Content

Positioning in 5G NR – A look at the technology and related test aspects

Radar, NFC, UV Sensors, and Weather Kits are Some of the New RAKwireless Products for IoT

5G Connectors: Enabling the global 5G vision

Control EMI with I-PEX ZenShield™ Connectors

Speed-up time-to-tapeout with the Aprisa digital place-and-route system and Solido Characterization Suite

Siemens Analogue IC Design Simulation Flow

More Sponsored Content >>

RSS Current EDABoard.com discussions

  • Smallest header needed to support PCB vertically above main PCB
  • What base emitter resistors are inside Darlington
  • Simulation of resonator in HFSS
  • series connection of power audio amplifier
  • Sampling with MOS transistor and cap

RSS Current Electro-Tech-Online.com Discussions

  • software PWM
  • ASM - Enhanced 16F and long calls - how?
  • Ampro 16mm Stylist projector woes.
  • Will Header and socket hold this PCB OK?
  • Passthrough charging-simple but impossible to achieve?

Oscilloscopes Product Finder

Footer

EE World Online

EE WORLD ONLINE NETWORK

  • 5G Technology World
  • Analog IC Tips
  • Battery Power Tips
  • Connector Tips
  • DesignFast
  • EDABoard Forums
  • Electro-Tech-Online Forums
  • Engineer's Garage
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips
  • Test and Measurement Tips
  • Wire & Cable Tips

EE WORLD ONLINE

  • Subscribe to our newsletter
  • Lee's teardown videos
  • Advertise with us
  • Contact us
  • About Us
Follow us on TwitterAdd us on FacebookConnect with us on LinkedIn Follow us on YouTube Add us on Instagram

Copyright © 2022 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy