• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Electrical Engineering News and Products

Electronics Engineering Resources, Articles, Forums, Tear Down Videos and Technical Electronics How-To's

  • Products / Components
    • Analog ICs
    • Battery Power
    • Connectors
    • Microcontrollers
    • Power Electronics
    • Sensors
    • Test and Measurement
    • Wire / Cable
  • Applications
    • 5G
    • Automotive/Transportation
    • EV Engineering
    • Industrial
    • IoT
    • Medical
    • Telecommunications
    • Wearables
    • Wireless
  • Learn
    • eBooks / Handbooks
    • EE Training Days
    • Tutorials
    • Learning Center
    • Tech Toolboxes
    • Webinars & Digital Events
  • Resources
    • White Papers
    • Design Guide Library
    • Digital Issues
    • Engineering Diversity & Inclusion
    • LEAP Awards
    • Podcasts
    • DesignFast
  • Videos
    • EE Videos and Interviews
    • Teardown Videos
  • EE Forums
    • EDABoard.com
    • Electro-Tech-Online.com
  • Bill’s Blogs
  • Advertise
  • Subscribe

Rapid cardiac biomarker testing system developed by Singapore scientists

December 8, 2009 By EurekAlert

Scientists at Singapore’s Institute of Microelectronics (IME)
have developed a rapid and sensitive integrated system to test
simultaneously for specific cardiac biomarkers in finger prick
amount of blood.

The silicon-based integrated system’s features could help
physicians quickly arrive at the right diagnosis for timely medical
intervention in patients suspected of having heart attacks —
particularly individuals who do not show obvious signs of chest
pains or shortness of breath, according to researchers at IME, one
of the research institutes sponsored by Singapore’s A*STAR (Agency
for Science, Technology and Research).

The IME-developed cardiac biomarker testing system significantly
cuts the time needed for sample preparation and analysis to just 45
minutes from the six hours typically required for the conventional
testing platform known as ELISA (Enzyme-linked Immunosorbent
Assay).

Because of its multiplexing capability – measuring several
cardiac biomarkers simultaneously — the new system contributes to
the detail and certainty of diagnosis.

“The key to saving lives in heart attack scenarios is time and
the quicker and more accurate the diagnosis can be made, the faster
proper care and treatment can be instituted,” said Philip Wong,
M.D., Senior Consultant at the Singapore National Heart Centre,
which worked with IME in developing the new system.

“The test kits can be rapidly deployed, and tests to confirm
clinical diagnosis can be completed within short time frames,” said
Dr. Wong. “As the kits are deployed on-site as opposed to a central
laboratory, confirmation of condition is rapid without the need to
transport patients’ specimens.”

The IME-developed system is a label-free technology that uses
semiconducting silicon nanowires (SiNWs) as biosensors. The working
principle behind the nanowire biosensors is the field-effect
transistor, which is responsible for generating a measurable
electrical response when specific antibody-antigen interactions
occur on the nanowire surface.

Specific antibodies that are immobilized onto the nanowire
surface will elicit antibody-antigen interactions when allowed to
come into contact with the variety of charged cardiac biomarkers.
Released into the blood when the heart is injured, cardiac protein
biomarkers such as troponin-T and creatinine kinases, are the basis
of medical tests of patients in which a heart attack is
suspected.

The IME-developed system is a label-free technology – thus
eliminating the tagging step, thereby saving time and reagent
consumption costs. In classical biochemical methods, the tagging of
a fluorescent dye to the targeted analyte is used to detect and
quantify the targeted analyte.

The IME-developed system’s parallel detection of several
biomarkers is made possible by the integration of the following
elements into one single microsystem:

  • In-built filtration to extract almost instantaneously the test
    serum from the whole blood sample
  • An array of SiNW chips coated with different antibodies for
    simultaneous detection of several biomarkers
  • A recording microchip for concurrent and immediate
    signal-readout from multiple SiNW sensors

The first demonstration of the full system capability revealed
impressive sensitivity and speed because it can attain in just
under 45 minutes a low detection limit of 1 pg/ml for cardiac
biomarkers, troponin-T and creatinine kinases, from 2 μl
blood.

Commercially available test kits require more than 1 ng/ml of
cardiac biomarkers in order for them to be detected, which is 1000
times less sensitive than the IME-developed system.

The technology and processes used for fabricating this
integrated device have yielded two patents to date.

“IME’s proprietary nanotechnology behind the new silicon-based
integrated system can be extended to other protein-based
diagnostics from blood and saliva samples to provide fast,
sensitive, accurate and portable solutions for protein-based
disease screening,” said Kwong Dim-Lee, Ph.D., IME’s Executive
Director.

Cardiac biomarkers, such as troponin-T and creatinine kinases
are proteins used for heart attack diagnosis. Troponin and
creatinine are constituents of the cardiac muscle cells that are
released into the blood when the cells and tissues are injured
after a heart attack. Hence elevated levels of troponin-T or
creatinine kinases in the blood alert the doctors that a heart
attack has taken place.

Troponin-T is established as a sensitive marker of myocardial
injury in the general population. The troponin-T level in the blood
increases within 4 to 6 hours after the onset of a heart attack and
peaks at about 24 hours. This increase lasts for 10 to 14 days.

Today, the first test performed on a patient who is suspected of
having a heart attack would be an electrocardiogram, commonly known
as the ECG. However, normal results from an ECG do not rule out the
occurrence of a heart attack, because the test is not sensitive
enough to detect minute anomalies in the reading, particularly when
the anomaly needs to be captured within a narrow time window of 2
– 30 minutes following the onset of a heart attack. When an
abnormal ECG reading cannot be established, the patient has to
undergo further blood tests to detect the relevant cardiac
biomarkers.

ELISA, which is the current method for detecting cardiac
biomarkers, uses fluorescent labeling technology. This biochemical
technique is laborious and time-consuming; the entire set-up
requires specialized personnel and instruments to implement,
thereby contributing to the per analysis cost. Hence, ELISA does
not favor prompt diagnosis for critical split-second medical
decisions.

SOURCE

You Might Also Like

Filed Under: Uncategorized

Primary Sidebar

EE Engineering Training Days

engineering

Featured Contributions

Meeting demand for hidden wearables via Schottky rectifiers

GaN reliability milestones break through the silicon ceiling

From extreme to mainstream: how industrial connectors are evolving to meet today’s harsh demands

The case for vehicle 48 V power systems

Fire prevention through the Internet

More Featured Contributions

EE Tech Toolbox

“ee
Tech Toolbox: Internet of Things
Explore practical strategies for minimizing attack surfaces, managing memory efficiently, and securing firmware. Download now to ensure your IoT implementations remain secure, efficient, and future-ready.

EE Learning Center

EE Learning Center
“ee
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for EE professionals.
“bills

R&D World Podcasts

R&D 100 Episode 10
See More >

Sponsored Content

Advanced Embedded Systems Debug with Jitter and Real-Time Eye Analysis

Connectors Enabling the Evolution of AR/VR/MR Devices

Award-Winning Thermal Management for 5G Designs

Making Rugged and Reliable Connections

Omron’s systematic approach to a better PCB connector

Looking for an Excellent Resource on RF & Microwave Power Measurements? Read This eBook

More Sponsored Content >>

RSS Current EDABoard.com discussions

  • Elektronik devre
  • Powering a USB hub: safely distributing current from a shared power supply
  • RF-DC rectifier impedance matching
  • How can I get the frequency please help!
  • 12VAC to 12VDC 5A on 250ft 12AWG

RSS Current Electro-Tech-Online.com Discussions

  • 100uF bypass Caps?
  • Fuel Auto Shutoff
  • Actin group needed for effective PCB software tutorials
  • how to work on pcbs that are thick
  • compatible eth ports for laptop
Search Millions of Parts from Thousands of Suppliers.

Search Now!
design fast globle

Footer

EE World Online

EE WORLD ONLINE NETWORK

  • 5G Technology World
  • Analog IC Tips
  • Battery Power Tips
  • Connector Tips
  • DesignFast
  • EDABoard Forums
  • Electro-Tech-Online Forums
  • Engineer's Garage
  • EV Engineering
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips
  • Test and Measurement Tips

EE WORLD ONLINE

  • Subscribe to our newsletter
  • Teardown Videos
  • Advertise with us
  • Contact us
  • About Us

Copyright © 2025 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy