• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Electrical Engineering News and Products

Electronics Engineering Resources, Articles, Forums, Tear Down Videos and Technical Electronics How-To's

  • Products / Components
    • Analog ICs
    • Connectors
    • Microcontrollers
    • Power Electronics
    • Sensors
    • Test and Measurement
    • Wire / Cable
  • Applications
    • Automotive/Transportation
    • Industrial
    • IoT
    • Medical
    • Telecommunications
    • Wearables
    • Wireless
  • Resources
    • DesignFast
    • Digital Issues
    • Engineering Week
    • Oscilloscope Product Finder
    • Podcasts
    • Webinars / Digital Events
    • White Papers
    • Women in Engineering
  • Videos
    • Teschler’s Teardown Videos
    • EE Videos and Interviews
  • Learning Center
    • EE Classrooms
    • Design Guides
      • WiFi & the IOT Design Guide
      • Microcontrollers Design Guide
      • State of the Art Inductors Design Guide
    • FAQs
    • Ebooks / Tech Tips
  • EE Forums
    • EDABoard.com
    • Electro-Tech-Online.com
  • 5G

Vertical Axis Wind Turbines Can Offer Cheaper Electricity

August 3, 2017 By American Institute of Physics

The computer-aided design model for one of the University of Utah’s design configurations for vertical axis wind turbines. The turbine blades are assumed to be made of carbon fiber and the turbine shaft and blade supports are made of Aluminum 2024. Image credit: Lam Nguyen and Meredith Metzger, Department of Mechanical Engineering at the University of Utah

According to a prediction made by the U.S. Department of Energy, wind energy could provide 20 percent of electricity in the U.S. by the year 2030. This has motivated researchers from the University of Utah’s Department of Mechanical Engineering to investigate the performance capabilities and financial benefits of vertical axis wind turbines (VAWTs) in urban and suburban areas.

A VAWT is a wind turbine design where the generator is vertically oriented in the tower, rather than sitting horizontally on top. While there are many VAWT designs, the one used in this study is called the straight-blade Darrieus type or H-rotor turbine.

According to the researchers, small VAWTs possess the ability to effectively operate in the presence of high turbulent flow, which makes them ideal energy harvesting devices in urban and suburban environments. In an article in this week’s Journal of Renewable and Sustainable Energy, from AIP Publishing, the authors present results indicating that an optimally designed VAWT system can financially compete with fossil-fuel based power plants in urban and suburban areas, and even spearhead the development of a net-zero energy building or city.

To establish their results, the team input actual, time-resolved wind speed data into a numerical simulation that determined the total amount of energy captured by a turbine over a year of operation. Their wind data was accrued over the year 2009 from 3-D sonic anemometers mounted on the top of traffic posts, about 9 meters, or 30 feet, above ground, and positioned at nine different urban and suburban sites around Oklahoma City, Oklahoma.

The researchers simulated 13 different wind turbine configurations, with a focus on four particular design parameters: height-to-diameter aspect ratio (H/D), blade airfoil shape, turbine solidity and turbine moment of inertia. The main performance measure used to identify the optimum design configuration was the percent of energy captured by the turbine over the course of the year relative to the available energy in the turbulent wind during the same time period.

Of the 13 design configurations, the optimal turbine design had the lowest moment of inertia. Interestingly, however, the researchers confirmed that even with the moment of inertia eliminated as a design parameter, this configuration was still the most ideal.

They also analyzed the various turbine designs for the levelized cost of energy (LCOE) at one of the test sites and found the values for blade characteristics necessary for economically viable options. The optimal design configuration at this site produced electricity at a cost 10 percent lower than the average national electricity unit price.

“This is not the end of our research, and I think that we have more to study on the turbine design configuration and its operating conditions that would allow for enhancing the amount of energy captured by the turbine. […] It’s exciting,” said Lam Nguyen, one of the lead researchers on the project. Nguyen is currently expanding his research with a former advisor.

Following their conclusion that an optimal design configuration for VAWTs could lead to a lower electric cost, the team knows the work is not finished.

DesignFast Banner version: 2cc828c3

Filed Under: Power Electronic Tips

Primary Sidebar

EE Training Center Classrooms

EE Classrooms

Featured Resources

  • EE World Online Learning Center
  • CUI Devices – CUI Insights Blog
  • EE Classroom: Power Delivery
  • EE Classroom: Building Automation
  • EE Classroom: Aerospace & Defense
  • EE Classroom: Grid Infrastructure
Search Millions of Parts from Thousands of Suppliers.

Search Now!
design fast globle

R&D World Podcasts

R&D 100 Episode 7
See More >

Current Digital Issue

Our second 5G Handbook is now available

Featuring 15 articles, the 2022 5G Handbook looks at private networks, timing, connectivity, latency, mmWaves, test, and other topics.

Digital Edition Back Issues

Sponsored Content

Positioning in 5G NR – A look at the technology and related test aspects

Radar, NFC, UV Sensors, and Weather Kits are Some of the New RAKwireless Products for IoT

5G Connectors: Enabling the global 5G vision

Control EMI with I-PEX ZenShield™ Connectors

Speed-up time-to-tapeout with the Aprisa digital place-and-route system and Solido Characterization Suite

Siemens Analogue IC Design Simulation Flow

More Sponsored Content >>

RSS Current EDABoard.com discussions

  • DC DC converter output voltage rise time
  • SMPS topology
  • LLC HB with synchronous rectifiers can be very dodgy?
  • Reducing switching noise in MOSFET inverter
  • Mathematical formula that converts voltage to weight the HX711 is using

RSS Current Electro-Tech-Online.com Discussions

  • Are Cross-wind compensation and Road crown compensation functions inputs to LKA function?
  • 500+V power supply from 9V battery using ZVS
  • IRFP450A replacement with IRFP460N on SIEG X2/LTF058213220 mini drill SIEG-FC350SMD Board
  • Sears Model 10656 Clock Radio - Clock board demanding high wattage resistor?
  • Trying to make a custom automated water container for my UV purifier. Can anyone help with where to begin?

Oscilloscopes Product Finder

Footer

EE World Online

EE WORLD ONLINE NETWORK

  • 5G Technology World
  • Analog IC Tips
  • Battery Power Tips
  • Connector Tips
  • DesignFast
  • EDABoard Forums
  • Electro-Tech-Online Forums
  • Engineer's Garage
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips
  • Test and Measurement Tips
  • Wire & Cable Tips

EE WORLD ONLINE

  • Subscribe to our newsletter
  • Lee's teardown videos
  • Advertise with us
  • Contact us
  • About Us
Follow us on TwitterAdd us on FacebookConnect with us on LinkedIn Follow us on YouTube Add us on Instagram

Copyright © 2022 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy