• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Electrical Engineering News and Products

Electronics Engineering Resources, Articles, Forums, Tear Down Videos and Technical Electronics How-To's

  • Products / Components
    • Analog ICs
    • Connectors
    • Microcontrollers
    • Power Electronics
    • Sensors
    • Test and Measurement
    • Wire / Cable
  • Applications
    • Automotive/Transportation
    • Industrial
    • IoT
    • Medical
    • Telecommunications
    • Wearables
    • Wireless
  • Resources
    • DesignFast
    • Digital Issues
    • Engineering Week
    • Oscilloscope Product Finder
    • Podcasts
    • Webinars / Digital Events
    • White Papers
    • Women in Engineering
  • Videos
    • Teschler’s Teardown Videos
    • EE Videos and Interviews
  • Learning Center
    • EE Classrooms
    • Design Guides
      • WiFi & the IOT Design Guide
      • Microcontrollers Design Guide
      • State of the Art Inductors Design Guide
    • FAQs
    • Ebooks / Tech Tips
  • EE Forums
    • EDABoard.com
    • Electro-Tech-Online.com
  • 5G

Odd ball application department: Using a scope to display SEM images

October 29, 2021 By Lee Teschler

The Applied Science YouTube channel run by Ben Krasnow (who in his day job is a hardware engineer at Verily, Google Life Sciences) focuses on interesting applications of science and technology. One video in particular caught our eye where Kranow uses an oscilloscope to help view digital images captured by a scanning electron microscope made by Jeol BV in the Netherlands.

Specifically, Krasnow uses a DSO having a long record length to capture details of SEM scans that last ten seconds or more. This is an interesting idea that potentially has application in other areas characterized by relatively long capture times. Krasnow used a Tektronix MDO3104 scope but the capture modes he employed can be found on many modern scopes. So we’ll review Krasnow’s approach here.

Krasnow’s SEM is an old device rescued from the trash. To capture images, the user normally attaches a Polaroid camera to an adapter and then holds the shutter open to capture a single frame from the SEM display. To get a high-resolution SEM image, it can take up to 60 seconds for the electron beam to scan across the sample. The reason for the long scan time is that electron microscopes work by focusing a beam of electrons onto the sample and then measuring the amount of emitted electrons reflecting back. High-rez images require that only a relative few accelerated electrons be beamed at and be reflected from the sample. So it takes a while for enough electrons to be accumulated to form any kind of an image.

Krasnow had the idea of using an oscilloscope with a sufficiently long record length to take the place of the Polaroid camera in recording images. What made this approach feasible was the availability schematics for the SEM. Krasnow probed the SEM PCB until he found the point where the video signal for slow scans was available. Also helpful was that the scan readout signal was on the order of about 90 V. He fed this signal to one scope channel. Krasnow also found a horizontal sync pulse which he used as a trigger. The data coming between each sync pulse represented one line of video. This setup produced a scope display that changed in shape and intensity as the SEM scan moved from the top of the screen to the bottom.

After maximizing the waveform on the DSO display to fill the entire screen, Krasnow changed the sampling mode to high resolution. The high-resolution mode on modern scopes basically performs averaging on the samples to effectively lower the noise floor. To get an image containing at least one megapixels, Krasnow chose a record length of five million. He used a vertical sync pulse (which happened once every 10 sec) as a trigger (with the scope in normal trigger mode) so that when the SEM starts a scan, the display triggers at the right point. Moreover, he used a pulse-width trigger so the display triggers when the pulse was greater than 500 μsec.

Krasnow also had to adjust the scope horizontal scale to capture the scan in one block. He used a 2 sec/div horizontal scale to fit one entire scan onto the scope screen.

Once the scope triggers, it takes a while for a display to appear. The reason is that in the normal trigger mode with capture rates on the order of 250k samples/sec, the scope doesn’t display anything as data gets acquired. Once the scope has recorded a whole video frame, the image really isn’t in a form that looks like a conventional SEM display. To clean things up, the frame can be saved as a file and loaded into a PC for some clean up. On Tek scopes, you can set cursors on the screen to select the portion of the display you want saved to a file.

For the clean-up, Krasnow used a program called Octave, which basically an open-source version of the Matlab analytics program. He wrote a script that put individual scan lines together to assemble an image raster-scan style. The result was a good rendition of the MEMS gyroscope target. There was a slight distortion that arose because Krasnow picked the signal off the SEM circuit board, slightly changing the portion of the target being imaged.

All in all, an interesting use of a scope’s ability to capture lengthy time periods.

You may also like:

  • Havana Syndrome
    Microwaves and the Havana Syndrome

  • Will 5G be lethal?

  • No, you can’t detect ghosts with a gauss meter

  • Old Scopes aren’t just for Old Codgers
DesignFast Banner version: 03e68ea8

Filed Under: Featured, Test and Measurement Tips Tagged With: FAQ, tektronix

Primary Sidebar

EE Training Center Classrooms

EE Classrooms

Featured Resources

  • EE World Online Learning Center
  • CUI Devices – CUI Insights Blog
  • EE Classroom: Power Delivery
  • EE Classroom: Building Automation
  • EE Classroom: Aerospace & Defense
  • EE Classroom: Grid Infrastructure
Search Millions of Parts from Thousands of Suppliers.

Search Now!
design fast globle

R&D World Podcasts

R&D 100 Episode 7
See More >

Current Digital Issue

Our second 5G Handbook is now available

Featuring 15 articles, the 2022 5G Handbook looks at private networks, timing, connectivity, latency, mmWaves, test, and other topics.

Digital Edition Back Issues

Sponsored Content

Positioning in 5G NR – A look at the technology and related test aspects

Radar, NFC, UV Sensors, and Weather Kits are Some of the New RAKwireless Products for IoT

5G Connectors: Enabling the global 5G vision

Control EMI with I-PEX ZenShield™ Connectors

Speed-up time-to-tapeout with the Aprisa digital place-and-route system and Solido Characterization Suite

Siemens Analogue IC Design Simulation Flow

More Sponsored Content >>

RSS Current EDABoard.com discussions

  • A circuit that can adjust a resistance and probing a voltage node
  • DC to DC buck converter
  • A circuit that can probe 2 currents and adjust the resistor
  • Microsoft Project 2019 dependencies
  • MOSFET ORing circuit simulation (LTspice)

RSS Current Electro-Tech-Online.com Discussions

  • Enclosure sought
  • Need help using a common power supply for two devices
  • Fletcher's Law
  • Setting the 18F24K20 to digital.
  • Multistage BJT amplifier

Oscilloscopes Product Finder

Footer

EE World Online

EE WORLD ONLINE NETWORK

  • 5G Technology World
  • Analog IC Tips
  • Battery Power Tips
  • Connector Tips
  • DesignFast
  • EDABoard Forums
  • Electro-Tech-Online Forums
  • Engineer's Garage
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips
  • Test and Measurement Tips
  • Wire & Cable Tips

EE WORLD ONLINE

  • Subscribe to our newsletter
  • Lee's teardown videos
  • Advertise with us
  • Contact us
  • About Us
Follow us on TwitterAdd us on FacebookConnect with us on LinkedIn Follow us on YouTube Add us on Instagram

Copyright © 2022 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy